OU Series Air Source Treatment Unit
The OU consisted of OR and OL, each unit can be orderd separately.
The OF with water separator cleans the compressed air of fluid oil, condensation and dirt Particles. For special application, the
The OR maintain imputting constant operating pressure despite fluctuation in line pressure and the amount of air consumed.
be added during operation. The oil drip rate is controlled by the adjustable bolt. Normally, 1 to 12 drops/1000L of the air is Suffcient.
standard 40 μ m filter element may easily be replaced by a 5 u m filterd element.
The proportinal lubricator adds a regulated quantity of oil to the filtered air. The oil-mist content proportional to the flow and oil can
Specifications
Service units | MINI | MIDI | MAXI | ||||||
ManualDrain | Working pressure: 12bar, 40μ m |
OU-1/8-MINI | OU-1/4-MINI | OU-3/8-MINI | OU-3/8-MIDI | OU-1/2-MIDI | OU-3/4-MIDI | OU-3/4-MAXI | OU-1-MAXI |
Manometer | 0˜12bar | OMA-40-16-1/8 | OMA-50-16-1/4 | ||||||
Medium | Compressed | ||||||||
Features of structure | Sintered fillter with water sparator; MINI/MIDI:MAXI:Pison redurator;Daiphagm type regurator:Direct constant-density lubricator | ||||||||
Mounting type | Pipe mounting or foot mounting | ||||||||
Assembly position | Vertical ±5º | ||||||||
Connection | G1/8″ | G1/4″ | G3/8″ | G3/8″ | G1/2″ | G3/4″ | G3/4″ | G1″ | |
Standard nominal flow rate OU-…(-A) | 700 | 1000 | 1200 | 2000 | 2600 | 2600 | 7000 | 8000 | |
Pimary Pressure | Manual condensate drain | 1˜16bar | |||||||
Autometic condensate drain | 1.5˜12bar | ||||||||
Working pressure | 0.5˜12bar | ||||||||
Min. Stand nominal flow rate | 3L/min | 6L/min | 10L/min | ||||||
Grade of filtration | 40μ m | ||||||||
Capacity of condendate fluid | 22ml | ||||||||
Temperature range | 0˜60ºC | ||||||||
Material information | Housing:Zinc die-casting; Filter bowl and oil bowl: PC; Meterial bowl guard: Aluminum alloy; Sealing: NBR; Adjusting knob: POM |